User manual
Maintenance Objects 
3-112V-PWR (12 Volt Power Supply) 
3
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
3
Maintenance Objects
NOTE:
This document is not intended to solve all troubles. When the limits of these 
procedures are reached and the problem is not resolved, escalate the 
problem to a higher level of technical support. Escalation must conform to 
the procedures in the 
Technical and Administration Plan
.
12V-PWR (12 Volt Power Supply)
The 12 Volt Power Supply unit in the Processor circuit pack is required for 
programming the on-board flash memory devices and the removable translation 
card. During the erase and write operations of a flash memory or translation card, 
the 12 volt power supply must be turned on by the software. For the read-only 
operation, the 12 volt power supply is not required.
If the 12-volt power supply cannot be turned on, all the erase and write 
operations to a flash device fail. Commands such as 
save translation
 and 
save 
announcements
 and features such as system upgrade, hard patching, and core 
dump always fail in this case.
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to 
Run Full Name of MO
12V-PWR MINOR test card-mem sh 12 Volt Power Supply
12V-PWR WARNING test card-mem sh 12 Volt Power Supply