User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Commands 
2-390upgrade software 
2
upgrade software
This command upgrades the software text image, the flash component of the 
LMM firmware, the MTP firmware, and the Processor Interface (PI) firmwares. In a 
simplex system, the command verifies that a software card-mem is present and 
then, if present, proceeds to reprogram the flash memory and perform a level-4 
restart. During the restart of the system, the system technician is prompted to 
replace the software card-mem with the translation card-mem. Service is 
provided upon completion of the system restart. Service down time is 5-12 
minutes.
!
WARNING:
Be sure to save translations before this executing this command. It may 
also be helpful to read the Feature Interactions for this command before 
upgrading the system software.
Time (ms)
Time from the board to each intermediate destination in 
milliseconds. If an error occurs at a node, the entry is repeated 
with an error code immediately following the time. Error codes and 
their meanings are:
■ ! Unable to reach port
■ !N Unable to reach network
■ !H Unable to reach host
■ !P Failure between endpoints
■ !F Need fragmentation of data packet
■ !S Source return failure
■ !X Packet blocked by filter
IP Address
The 32-bit network address.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
upgrade 
software
none init
inads
craft
none See below