User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Commands 
2-383test tone-clock 
2
test tone-clock
The test tone/clock command performs hardware diagnostic tests on a specified 
tone or clock circuit pack.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
test 
tone-clock
location
short
long
repeat 
number
clear
schedule
PCSS
Option for a brief series of 
nondestructive diagnostic tests.
Option for a longer, more 
comprehensive series of both 
destructive and nondestructive 
diagnostic tests.
How many times each test in the 
sequence is repeated (1-100)
This option causes the test 
sequence (short or long) to repeat 
until the alarm (if any) is cleared or 
a single test in the sequence fails.
1
Command is validated and then a 
scheduling form displays to 
schedule execution of the 
command. The command is then 
placed in the command queue and 
is executed at the specified time. 
The information displayed by the 
command is sent to the system 
printer instead of the screen.
2
Examples:
test tone-clock 01a l 
test tone-clock 01b l schedule
1 If no alarms are registered against the maintenance object then the test sequence is run only once. The
 long clear
option forces a clear of all alarms if no errors are encountered during testing. The 
short clear
 option only clears 
alarms pertinent to tests in the short sequence.
2 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
Test 
Sequence 
= short; 
Repeat = 
1
none