User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Commands 
2-380test sys-link 
2
Output
The following example shows the output from the 
test sys-link 01A0516 current 
command.
Field descriptions
Port
Port address
Maintenance 
Name
Maintenance object name
Alt. Name
Alternate means of identifying the link
Test No.
Test being executed
Result
Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Error Code
Numeric code explaining why the release failed or aborted. Refer 
to the detailed list of the codes by test number for each MO.
 test sys-link 01A0516 current  Page 1 SPE A
 TEST RESULTS
 Port Maintenance Name Alt. Name Test No. Result Error Code
 01A0516 SYS-LINK PRI 985 PASS
 01A PKT-INT 886 PASS 
 01A PKT-INT 887 PASS 
 PN 01A TDM-BUS 294 PASS 
 PN 01A TDM-BUS 296 PASS 
 press CANCEL to quit -- press NEXT PAGE to continue