DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Commands 
2-378test sys-link 
2
Output
The following screen is an example of the output for the 
test synchronization 
short
 command. The responses are displayed on a test-by-test basis with one 
line of data for each test result.
Field descriptions
test sys-link
This command validates the specified link and runs diagnostic tests on the 
hardware objects that comprises the system link. If the 
current
 or 
faulted
 options 
are specified, tests are run on all hardware objects that comprise the specified 
link. If 
current
 or 
faulted
 is not specified, only the end-to-end sys-link connection 
is tested.
The hardware path that comprises a system link consists of up to 21 hardware 
components that affect the behavior of the link. The number of components of a 
given system link hardware path depends on the system configuration and type 
of system link.
Port
Not applicable
Maintenance 
Name
Maintenance object name
Alt. Name
Not applicable
Test No.
Test being executed
Result
Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Error Code
Numeric code explaining why the release failed or aborted. Refer 
to the detailed list of the codes by test number for each MO.
 test synchronization short
 TEST RESULTS
 Port Maintenance Name Alt. Name Test No. Result Error Code
 SYNC 417 PASS
 Command Successfully Completed