User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Commands 
2-358test network-control 
2
Output
The following example shows the output from the 
test network-control a
command. The responses display on a test-by-test basis with one line of data for 
each test result.
Field descriptions
Port
Port address: cabinet (always 1)-carrier-slot-circuit. For the 
DATA-BD, SW-CTL, 12V-PWR, and CARD-MEM maintenance 
objects, the 
slot
 and 
circuit
 fields of port address are blank. 
DATA-CHL (administered data channel) uses 
XX
 as the slot 
address and has a circuit number between 01 and 04. The carrier 
field has a value 
A
 for the control carrier A in a simplex system.
Maintenance 
Name
The name of the maintenance object
Alt. Name
Extension number of the DATA-CHL, if administered. For other 
maintenance objects, this field is not applicable and, therefore, 
empty.
Test No
The test being executed
Result
Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Error Code
Numeric code explaining why the release failed or aborted. Refer 
to the detailed list of the codes by test number for each MO.
 test network-control a
 TEST RESULTS
 Port Maintenance Name Alt. Name Test No. Result Error Code
 01A DATA-BD 52 PASS
 01A0101 DATA-CHL 4001 109 PASS
 01A0101 DATA-CHL 4001 110 PASS
 01A0101 DATA-CHL 4001 111 PASS
 01A SW-CTL 95 PASS
 01A SW-CTL 92 PASS
 01A SW-CTL 94 PASS
 01A SW-CTL 324 PASS
 01A 12V-PWR 701 PASS
 01A CARD-MEM 695 PASS
 01A CARD-MEM 696 PASS
 01A CARD-MEM 697 PASS
 01A CARD-MEM 698 PASS
 01A CARD-MEM 699 PASS
 Command Successfully Completed