Maintenance Commands 
2-290status packet-interface 
2
Field descriptions, page 1
Only those fields that are different from 
‘‘status link n’’
 are listed here.
status packet-interface
This command displays the status of the packet-interface portion of the TN798 
processor circuit pack along with link information. Link status information 
including total, active, and failed links also display. When the packet-interface is 
out-of-service or uninstalled, it is not used to establish and maintain links; when it 
returns to in-service status, new links are again assigned to it.
Output
The following example shows the output from the 
status packet-interface 
command.
Destination
Name of the destination (assigned with the 
add/change 
data-module
 command)
Destination Status
in-service/idle, in-service/active, disconnected, out-of-service, 
in-service, inactive, active, idle
AC
Active channel
Destination Port
Administered port location (assigned with the 
add/change 
data-module
 command)
Destination 
Extension
Administered destination extension number (assigned with the 
add/change data-module
 command). This may be replaced by 
Trk/Mem data (like the PI status line form) depending upon the 
type of destination.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
status packet- 
interface
print
Report sent to printer init
inads
craft
none none
 status packet-interface
 PACKET INTERFACE STATUS
 Location: 01A
 Service State: in-service 
 Total Links: 32 
 Active Links: 32 
 Failed Links: 0 