Maintenance Commands 
2-234status card-mem 
2
status card-mem
Memory cards are portable, compact memory cards that contain banks of flash 
EPROM chips. Non-volatile memory cards are eraseable and randomly 
programmed with user data. Main memory stores system software in its “flash” 
section. Memory cards that save translations do not contain copies of the system 
software. During system reboot or system power down conditions, in-core system 
maintenance hardware error logs temporarily save in memory cards before the 
ASAI 0-126 Hyperactive ignore ignore Link has sent too many messages 
per unit time.
BRI Signaling suspends. System 
timeouts in 60 seconds and 
attempts reactivate the link. If links 
remain in this state while no activity 
occurs at BRI endpoints:
1. Ensure that SPID switch 
administration and endpoints 
are consistent. Verify repairs by 
executing the status bri-port 
PCSSpp command. Determine 
that the L2 state of the signaling 
link is L3-Established. 
2. Replace the endpoint. Verify 
repairs by executing the status 
bri-port PCSSpp command. 
Determine that the L2 state of 
the signaling link is 
L3-Established. 
ASAI 0-126 L3-Restarting ext The switch sends a Restart 
message to the adjunct but has not 
received a Restart Acknowledgment 
message from the adjunct.
ASAI 0-126 L3-Restarted ext After receiving a Restart 
Acknowledgment message, the 
switch sends a Heartbeat message 
to the adjunct and awaits a 
response.
ASAI 0-126 L3-Established ext Normal state for ASAI adjunct.
Table 2-3. Status BRI-Port Command Interpretation — Continued
Endpoint 
Types
TEI 
Range Layer 2 State
Voic e 
Extension
Service 
SPID Description / Recommendation
Continued on next page