User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Commands 
2-219status audits 
2
Output
The following example shows the output from the 
status attendant 1 
command.
Field descriptions
status audits
This command displays results of Data Relation Audits that are built into the 
switch. Data Relation Audits check for inconsistencies between selected data 
items in the switch, and report inconsistencies. Data Relation Audits are useful 
during development and testing phases of projects to uncover software errors. In 
the field they help the switch to recover from data corruption before service is 
interrupted.
This command displays the date and time that the requested interval begins, the 
number of times that the full sequence of audits executes (audit cycles), and 
status information about each audit that detected a problem or aborted during 
the interval. The status information contains:
■ The name of the audit 
■ The number of times that an audit ran and corrected an error 
■ The number of times that an audit ran and detected an irreparable error
■ The number of times that an audit ran and aborted
Console Number
Number assigned to the attendant (1-16).
Port
Port location of the attendant (cabinet-carrier-slot-circuit).
Service State
In-service/idle, in-service/active, out of service, or 
disconnected.
Usage State
Idle or active.
Maintenance Busy State
Is maintenance testing the object? (y or n)
Connected Ports
Port locations to which the attendant is communicating 
(cabinet-carrier-slot-circuit).
 status attendant 1
 ATTENDANT STATUS
 Console Number: 1 Service State: in-service/night service
 Port: 01C1106 Download Status: no
 Connected Ports:
 Command successfully completed