User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Commands 
2-214set tone-clock 
2
Field descriptions
set tone-clock
This command sets the active tone/clock for a PN that has a duplicated 
tone/clock circuit pack. Technicians should reset the default active tone clock in 
each PN after using the 
set tone-clock
 command. If it is not in use, a single 
failure can cause an unnecessary service outage. The schedule maintenance 
tone-clock switch option does not reset the tone-clock to the default active if it 
was not active at the beginning of the test.
set vector
This command specifies restart levels for core dumps and places core dumps on 
primary Mass Storage System (a tape in a tape system and core dump memory 
cards in a memory card system) devices for later examination. The 
set vector
command allows technicians to tailor restart levels that copy memory to primary 
Mass Storage System devices.
NOTE:
Software never requests an extended reboot.
To force an immediate core dump, set the appropriate bit using this command, 
then enter the 
reset system
 command at a level that forces core dumps 
corresponding to set vector bits.
When a system restart occurs in a simplex system with the corresponding vector 
bit set, the core dump writes to secondary storage (the primary MSS device). 
Once the core dump writes, the vector clears and the restart executes.
Day of the Week:
Monday through Sunday
Day of the Month:
1-31; the system also checks for leap year.
Month:
January through December
Year:
1970-2999
Hour:
0-23
Minute:
0-59
Second:
The system sets this field to zero when the time of day clock is set.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
set tone-clock
location 
override
Tone/clock location: 
PC
Forces the set command into 
effect regardless of the tone/clock 
circuit pack’s health.
init
inads
craft
1 (one) none