Maintenance Commands 
2-152list testcalls 
2
The measurements are produced by a set of analog trunk tests. The tests are 
initiated by a maintenance demand test or by a set of scheduled tests. The 
largest portion of these measurements are generated through scheduled testing 
during system quiet hours (hours where the traffic volume is low). Each trunk test 
performed by the system stores the results in a database. The trunk 
measurements in this database reflect the state of each trunk at the time of its last 
test.
Action/Object Qualifiers/Options Qualifier/Option Description
list testcalls
detail
summary
Detailed measurement report displayed
Summary measurement report displayed
grp group number Measurements for a specific trunk group displayed. When used 
with the 
to-grp
 option, this option is the starting trunk group in a 
range of user-specified trunk groups.
to-grp group number Measurements for all trunk groups from 1 to the specified 
βto-grpβ trunk group are displayed. When used with the 
grp
option, this option is the ending trunk group in a range of 
user-specified trunk groups.
mem member number Measurements for a specific trunk group member displayed. 
When used with the 
to-mem
 option, this option is the starting 
trunk group member in a range of user-specified trunk group 
members.
to-mem member number Measurements for all trunk group members from 1 to the 
specified βto-memβ trunk group member displayed. When used 
with the 
mem
 option, this option is the ending trunk group 
member in a range of user-specified trunk group members.
port location Measurements for a specific trunk circuit (port) displayed
result result identifier This option is used to filter out all measurement results that do 
not match the user-specified result, that is, only measurement 
results that match the user specified result are displayed. 
Examples of results are pass, marg, fail, etc.
not-result result identifier This option is used to filter out all measurement results that do 
match the user-specified result, that is, only measurement 
results that do not match the user specified result are displayed. 
Examples of results are pass, marg, fail, etc.
count count number This option is used to specify (limit) the number of records 
displayed.
print Report sent to printer
schedule Command is validated and then a scheduling form displays to 
schedule execution of the command. The command is then 
placed in the command queue and is executed at the specified 
time. The information displayed by the command is sent to the 
system printer instead of the screen.
1