User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Commands 
2-111list history 
2
Field descriptions
list history
This command generates a log listing of the most recently completed “data 
affecting” administration and maintenance commands. Data commands are 
those administration and maintenance commands that change the data state 
associated with any object and qualifier in the system. Administration data 
commands affect translation data, while maintenance data commands affect 
state information. For example, 
change station
 is a data command, whereas 
display station
 is not.
All information in the transaction log is saved on tape as translation data when 
the 
save translation
 command is performed (LIFO order). When the switch 
COLD I starts or reboots, the saved translation, and thus the transaction log, is 
loaded from tape. In this way, the translation data and the data in the transaction 
log remain compatible.
Port
Port address
1
1 The special locations UUmajor and UUminor (see Screen 2-6) designate the name of the major 
or minor maintenance circuit pack alarm connection for cabinet UU (depends upon the auxiliary 
connector of the Port Network). Thus, both a “major” and “minor” port can be administered with 
major, minor, or warning alarms.
Alarm Type
The alarm level for this external device alarm port. Entries are 
major
, 
minor
 (default), or 
warning
.
Alt. Name
7-character adjunct short name for this external device alarm
Description
40 character adjunct description for the external device alarm
Product 
Identifier
10-digit product identifier of the external device alarm (leading 
zeroes are significant and retained). If the field is blank (default), 
alarms associated with the connected adjunct use the switch 
product identifier administered on the Change System-Parameters 
Maintenance screen.
Building
A 40-character description of the external device alarm’s building 
location
Address
A 40-character building address