User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Commands 
2-77display system-parameters duplication 
2
Field descriptions
display system-parameters duplication
This command displays the status (enabled or disabled) of Switch Processing 
Element (SPE) and Port Network Connectivity (PNC) duplication. The following 
must be duplicated:
■ Each switch node record and every switch node with its duplicate (cabinet 
administration is a prerequisite)
■ Every fiber link containing either an expansion interface circuit pack as an 
endpoint, or a DS1-C (fiber link administration is a prerequisite; circuit 
pack administration then follows duplication administration)
Stratum:
Synchronization stratum that is used (3 or 4)
Primary:
First choice system synchronization source (blank = no 
synchronization); valid only if stratum 4 synchronization specified
Secondary:
Second choice system synchronization source (blank = no 
synchronization); valid only if stratum 4 synchronization specified
Location:
Circuit pack location (cabinet-carrier-slot) of all administered DS1 circuit 
packs are listed here.
Name:
User-defined name administered for the DS1 circuit pack. Blank means 
no user-defined name administered.
Slip:
If the DS1 circuit pack has slip alarm, field shows 
y
; otherwise, 
n
.
Port 
Network:
Stratum 3 only; specifies the port network supplying synchronization 
through the tone clock circuit pack.
display synchronization Page 1 of 2
 SYNCHRONIZATION SOURCE (Synchronization Plan circuit pack location)
 Stratum: 4
 Primary: Secondary:
 DS1 CIRCUIT PACKS
 Location Name Slip Location Name Slip
 01C10 D92D1 ds1 1c10 n
 01C11 D92D1 ds1 1c11 n
 NOTE: DS1 and BRI Trunk sources result in stratum 4, type II synchronization