User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Commands 
2-69display initcauses 
2
The following example shows a typical vector event report.
Field descriptions
display initcauses
The 
display initcauses
 command displays a history of recovery steps taken by 
the system. Each time the system performs some type of recovery (due to user 
request or a hardware or software problem), the recovery information is stored. 
The software error log also contains information pertaining to restarts. If a reset 4 
(reboot) occurs, the software error log is also be stored. Information in the 
software error log should be used in conjunction with information in the initcauses 
log.
The history of the last 16 restarts performed by the system will be recorded to the 
initcauses buffer in chronological order. This buffer fills an entire screen with 
information if it is completely full. Power failures in the processor complex wipe 
out the entire initcauses buffer.
Event Type
A number from 50000 to 50999 that identifies what type of vector event 
occurred.
Event 
Description
A text string describing the event.
Event Data 1
If in the format 
number
/
number
 such as “200/10”, this indicates the 
vector number and step number associated with the event. If in the 
format “Split 
number”
 such as “Split 2”, this indicates the split number.
Event Data 2
Additional data concerning the event encoded as a hex number.
First Occur
The date and time when the vector event first occurred.
Last Occur
The date and time when the vector event last occurred.
Evnt Cnt
The total number of times, up to 255, that vector events of this type 
have occurred.
 display events Page 1 SPE B
 EVENTS REPORT
 Event Event   Event Event First  Last  Evnt
 Type Description   Data 1  Data 2 Occur  Occur  Cnt
 50020 Call not queued  256/5 B 09/28/13:43 09/28/13:43 1
 50541 Not a messaging split Split 89 4C 09/28/13:43 09/28/13:43 1