Maintenance Commands 
2-46display alarms 
2
Field descriptions
Port
Lists the location codes for the alarmed object, as follows:
■ Circuit packs locations display as: 
cabinet-carrier-[slot]-[circuit]. Example: 
01C0702
.
■ Port network locations display as: port network number-bus. 
Example: 
PN 02B
. PN 02 = Port Network (PN) number and A 
or B = bus.
■ Fiber link locations display as: fiber link number-PNC side. 
Example:
 x A-PNC
. “X” = fiber link number and “A” = PNC 
side [A or B]. 
Maintenance 
Name
Lists the logical name of the maintenance object with the alarm.
On Brd
A 
y
 (yes) indicates the fault was found on the associated circuit 
pack. A 
n
 (no) indicates the fault is 
not
 connected to the circuit 
pack.
Alt Name
Identifies the location of maintenance object, as follows:
■ Station = extension number 
■ Trunk = Group number (78/__) or group and member 
numbers (78/01)
■ Private CO Line = private CO line (P) and group number. 
(P/xxx)
Alarm Type
Alarm level: MAJOR, MINOR, or WARNING
Service State
Service state of the station and trunk ports:
■ RDY = ready for service
■ OUT = out of service
■ IN = in service