User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Commands 
2-43display alarms 
2
System resets, that are less severe than a reboot, rarely affect the error and alarm 
logs.
NOTE:
If the error and alarm logs contain SYSTEM errors, then use the 
display 
initcauses
 command to search for information that system could 
not
 log 
during reset operation.
Feature Interactions
■ If the user disables the alarm origination with the 
change 
system-parameters maintenance
 command, then the 
Ack?
(Acknowledged) field on the Alarm Report is blank regardless of the true 
acknowledged state of the alarm.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
display alarms
print
schedule
Report sent to printer
Command is validated and then 
a scheduling form displays to 
schedule execution of the 
command. The command is then 
placed in the command queue 
and is executed at the specified 
time. The information displayed 
by the command is sent to the 
system printer instead of the 
screen.
1
Examples:
display alarms
display alarms print 
display alarms schedule
1 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
cust
rcust
bcms
browse
all alarms 
displayed
See below