Maintenance Commands 
2-32change system-parameters maintenance 
2
Test Type 102
Test Type 102 tests far end to near end loss by sending:
■ 9 seconds of 1004 Hz tone at 0 dB
■ 1 second of quiet
■ This cycle is repeated until disconnect; disconnect is forced 
after 24 hours.
Test Type 105
Test Type 105 tests 2-way loss, gain slope, and C-message and 
C-notch noise by sending:
■ nine seconds of 1004 Hz at -16 dB
■ one second of quiet
■ nine seconds of 404 Hz at -16 dB
■ one second of quiet
■ nine seconds of 2804 Hz at -16 dB
■ 30 seconds of quiet
■ one-half second of Test Progress Tone (2225 Hz)
■ approximately five seconds of quiet
■ forced disconnect
ISDN Maintenance
ISDN-PRI Test 
Call Extension
This field indicates the extension used by far-end ISDN nodes to 
place calls to the system, for testing ISDN-PRI trunks between 
the far-end and the system.
ISDN-BRI Service 
SPID
This field shows if the link associates with the Service SPID. If the 
link is associated with the Service SPID. This number is the test 
SPID (0 – 99999) (under BRI-SET MO). Otherwise, this field is 
blank. Service SPID is a feature used by the system technician to 
check building wiring between the switch and the BRI endpoint.
DS1 Maintenance
DSO Loop-Around 
Test Call 
Extension
The extension used to set up a DSO loop around connection for 
testing non-ISDN DS1 trunks. The DSO Loop-Around Test Call 
feature is used primarily for testing DSO channels associated 
with non ISDN-PRI trunks. The loop-around is activated by dialing 
the test extension number; multiple DSO Loop-Around 
connections can be established by placing multiple calls to the 
loop-around extension.