User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
 Maintenance Objects
3-1289XXX-BD (Common Port Circuit Pack) 
3
If the circuit pack is not in the system, insert a circuit pack (in the same 
slot as the error indicates) to resolve this error. Or, if the circuit pack is in 
the system and the red LED is on, follow the instructions for "Red (alarm)" 
in the ‘‘Control and Port Circuit Pack Status LEDs’’
 section in Chapter 1, 
‘‘Maintenance for csi systems’’
b. This error indicates the circuit pack has been busied out. Release the 
circuit pack via 
release board PCSS
.
c. The circuit pack has been logically administered but not physically 
installed. The alarm should clear when the circuit pact is installed.
If the circuit pack is already installed:
1. Run 
test board PCSS long
 and look at any test failures or error 
codes generated.
2. If the test does not clear error 23, then execute 
reset board PCSS
and run the long test again.
3. If the reset/test does not clear error 23, replace the circuit pack. 
d. A wrong circuit pack is inserted in the slot where this circuit pack is 
logically administered. To resolve this problem, either remove the wrong 
circuit pack and insert the logically administered circuit pack OR use the 
change circuit-pack
 command to readminister this slot to match the 
circuit pack inserted.
e. This error indicates transient communication problems with this circuit 
pack. This error is not service-affecting and no action is required.
f. This error, when reported with Aux data in the range of 4352 to 4358, 
indicates that the circuit pack has reported an on-board hardware failure. 
The circuit pack continuously tests the hardware and report the results 
approximately every 10 minutes. If the hardware problem is resolved, the 
"leaky bucket" strategy should clear the alarm in approximately 30 
minutes. However, if the alarm does NOT clear in 30 minutes, the circuit 
pack should be replaced.
g. This error can be ignored, but look for other errors on this circuit pack.
h. This error is not service-affecting and no action is required.
i. This error indicates that no ringing current is detected. Run Test #51, 
Ringing Application Test, and follow the procedures for Test #51. This error 
is only applicable to Analog Line circuit packs.
j. The hyperactive circuit pack is out-of-service and may exhibit one or more 
of the following symptoms:
1. The common circuit pack level tests such as Test #51 and/or Test 
#220 are aborting with error code 2000.
2. The tests run on the ports of this circuit pack are returning with a 
NO-BOARD.
3. A busyout/release of the circuit pack has no affect on test results.