User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
 Maintenance Objects
3-1283WAE-PORT (Wideband Access Endpoint Port) 
3
Port Audit and Update Test (#36)
This test sends port level translation data from switch processor to the UDS1 
Interface circuit pack to ensure that the wideband access endpoint port’s 
translation is correct.
Table 3-548. TEST #7 Conference Circuit Test 
Error 
Code
Te st 
Result Description/ Recommendation
ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may 
be in use on a valid call. Use the status access-endpoint <extension> 
command to determine when the port is available for testing.
1004 ABORT The port has been seized by a user for a valid call. Use the status 
access-endpoint <extension> command to determine when the port is 
available for testing. The port is available when it is in the in-service/idle 
state.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1020 ABORT The test did not run due either to a previously existing error on the specific 
port or to a more general circuit pack error.
1. Examine the Error Log for existing errors against this port or circuit 
pack, and attempt to diagnose the previously existing error.
2000 ABORT Response to the test request was not received within the allowable time 
period.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The NPE of the tested port did not conference the tones correctly. This 
causes noisy and unreliable connections. Although wideband calls do not 
use the conferencing feature on the NPE, this failure indicates problems 
with the circuit pack hardware.
1. Replace the circuit pack.
PASS The port can correctly conference multiple connections.
1. User-reported troubles on this port should be investigated by using 
other port tests and by examining the terminal adapter or the external 
wiring.
Continued on next page