User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Commands 
2-16busyout tdm 
2
Output
The following example is a display of the 
busyout station
 command.
Field descriptions
busyout tdm
The 
busyout tdm
 command places the specified tdm bus in a maintenance 
busy state. No periodic or scheduled tests are performed on the busied out bus 
until it is released. When the object is maintenance busy it is deactivated (no call 
processing activity may include the busied object). Warning alarms (error type 
18) are generated on each busied out tdm bus, so that INADS can determine the 
state of the objects. The command, 
release tdm
, reactivates the specified tdm 
bus.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
busyout 
station
extension
Extension number (per 
dial-plan)
Examples:
busyout station 10020 
busyout station 32770
init
inads
craft
none none
Port
Port address (cabinet-carrier-slot-circuit)
Maintenance Name
Type of busied out maintenance object
Alt. Name
Alternate means to identify maintenance object: extension 
number
Result
Test result: Pass, Fail, Abort
Error Code
Numeric code explaining why the release failed or aborted. Refer 
to the detailed list of the codes by test number for each MO.
 busyout station 1002 SPE A
 COMMAND RESULTS
 Port Maintenance Name Alt. Name Result Error Code
 01C1102 DIG-LINE PASS
 Command successfully completed