 Maintenance Objects
3-1255UDS1-BD (UDS1 Interface Circuit Pack) 
3
Table 3-536. TEST #1227 ICSU Status LEDs Test 
Error 
Code
Tes t 
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1005 ABORT The ICSU Status LEDs test can not be executed for the current configuration. 
The test applies only to TN464F or later UDS1 circuit packs administered for 
24-channel operation (1.544 bit rate).
1. If the circuit pack is a TN464F or later suffix UDS1 circuit pack, then retry 
the command.
1951 ABORT The ICSU Status LEDs Test can not be executed because a 120A1 or later 
suffix CSU Module or a 401A or later suffix T1 Sync Splitter is not physically 
installed. If using a 120A1 CSU Module or the 401A T1 Sync Splitter, physically 
connect it to the TN464F board on the back of the port carrier. Otherwise, 
ignore this abort.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2500 ABORT Internal system error.
1. Retry the command.
Continued on next page