User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
 Maintenance Objects
3-1246UDS1-BD (UDS1 Interface Circuit Pack) 
3
One-Way Span Test (#1214)
This test is destructive.
The One-Way Span Test allows one-way span testing to and from remote test 
equipment or another DEFINITY communications system. This will test all 
circuitry and facilities from the local TN464F DS1 board to the remote test 
equipment or other DEFINITY communications system.
The test is destructive and can only be initiated by a system technician 
demanded 
test ds1-loop UUCSS one-way-span-test-begin
 command.
All trunks or ports on the UDS1 Interface circuit pack must be busied out via the 
system technician 
busyout board
 command before running the One-Way Span 
Te s t .
The One-Way Span Test has the TN464F UDS1 Interface circuit pack transmit a 
framed 3-in-24 test pattern and attempt to receive and verify the pattern. If the 
TN464F board receives a framed 3-in-24 test pattern sent from another DEFINITY 
G3V3 or test equipment at the far-end of the DS1, it will begin counting bit errors 
within the received pattern.
The status of the One-Way Span test will be available in the hardware error log 
via error type 3902. Several distinct aux values will be used to give the user 
information of the status of the test.
The 
list measurements ds1 summary
 command will display the length of time the 
test has been running (
Test Duration
 field) and number of bit errors detected 
(
Loopback/Span Test Bit-Error Count
 field). If the test pattern is being sent 
cleanly over the span from the far-end, the number of bit errors should be very 
low. The 
Te s t  D u r a t i o n
 field will show 
0
 until the test pattern is received from the 
far-end. Upon receiving the test pattern, the board will begin calculating the test 
duration and number of bit errors. The command will also display the 
Loopback/Span test executing (
Tes t 
field), the type of pattern generated for the 
Loopback/Span test (
Pattern 
field), and whether the pattern (
i.e.
3-in-24 Pattern
) 
is synchronized (
Synchronized 
field).
To terminate the test, enter the 
test ds1-loop UUCSS end-loopback/span-test
command or the 
release board
 command. Using the 
release board
 command 
will restore all trunks or ports on the TN464F UDS1 Interface circuit pack to the 
in-service state.