User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
 Maintenance Objects
3-1219UDS1-BD (UDS1 Interface Circuit Pack) 
3
Slip Alarm Inquiry Test (#144)
Slips occur when transmitter and receiver are not running at precisely the same 
clock rate. The UDS1 Interface circuit pack can detect both positive and 
negative slips on the DS1 facility. The Slip Alarm Inquiry Test is used to acquire 
the total number of slips that have occurred on a DS1 link.
When the UDS1 Interface circuit pack detects a slip condition, the circuit pack 
will increase the on-board slip counter by 1. A SLIP-COUNT message is 
spontaneously sent to the system software after the counter reaches a threshold 
(for example, 88). When the maintenance software receives the SLIP-COUNT 
message, the Slip Alarm Inquiry Test is initiated to query the slip counters on a 
UDS1 Interface circuit pack and total the slip counts in the maintenance 
software.
If the count of slips is over the threshold, a Minor alarm is raised against the 
UDS1 Interface circuit pack. All trunks or ports of the UDS1 Interface circuit pack 
remain in the in-service state. If the UDS1 Interface circuit pack is used to supply 
the system synchronization source, the MINOR alarm will initiate a 
synchronization source switch. See “TDM-BUS” and ‘‘SYNC (Synchronization)’’
for details.
  PASS No Minor alarm is detected in the UDS1 Interface circuit pack.
0NO 
BOARD
The test could not relate the internal ID to the port (no board). This could be due 
to incorrect translations, no board is inserted, an incorrect board is inserted, or 
an insane board is inserted.
1. Ensure that the board translations are correct. Execute the add ds1 UUCSS 
command to administer the UDS1 interface if it is not already administered.
2. If the board was already administered correctly, check the error log to 
determine whether the board is hyperactive. If this is the case, the board is 
shut down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, then issue the 
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
Table 3-524. TEST #143 Minor Alarm Inquiry Test — Continued
Error 
Code
Tes t 
Result Description/ Recommendation
Continued on next page