User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Commands 
2-8busyout journal-printer 
2
Feature Interactions
Maintenance of a particular component on a link sometimes interferes with the 
maintenance of the link itself. For example, maintenance can put a link 
component in a busy state causing link set-up to fail. Frequent attempts at 
re-setup of a link may delay the recovery of a faulty component, due to the 
maintenance test of a component only taking place when the component is idle. 
Therefore, disable the attempted re-setup of a link with the busyout command 
and the link will remain intact. If the link is already down, the busyout command 
stops periodic re-setup attempts on the link.
Output
The following example shows the output for the 
busyout journal-printer 
wakeup-log
 command.
Field descriptions
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
busyout 
journal-printer
pms-log
wakeup-
log
Link to pms (in output, port name for 
pms link =1)
Link to the wakeup logging facility (in 
output, port name = 0)
Examples:
busyout journal-printer pms-log 
busyout journal-printer wakeup-log
init
inads
craft
nms
None See below
Port
Physical object port address: 
0
 = wakeup log, 
1
 = pms log
Maintenance Name
The name of the maintenance object
Alt. Name
Not applicable
Result
Test result: Pass, Abort, Fail
Error Code
Numeric code explaining why the release failed or aborted. Refer 
to the detailed list of the codes by test number for each MO.
 busyout journal-printer wakeup-log SPE A
 COMMAND RESULTS
 Port Maintenance Name Alt. Name Result Error Code
 0 JRNL-LINK PASS