User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
 Maintenance Objects
3-1161TTR-LEV (TTR Level) 
3
3. Execute the 
display error
 command. Look for a GPTD-PT, DTMR-PT, or 
CLSFY-PT that has been busied out. A port that has been busied out has a 
value of 18 in the error type field of the Hardware Error Log.
For each of the busied-out ports, use the following procedure:
■ Determine why the port was busied out.
■ If the port can be placed back into service, test the port via the 
test 
port PCSSpp
 command.
■ If all the tests pass, release the port via the 
release port PCSSpp
command. Then wait one minute for the TTR Level alarm to clear.
If this does not clear the TTR Level alarm, proceed to Step 4.
4. Execute the 
display alarm
 command. Determine the address of the Tone 
Detector circuit pack which contains the defective (alarmed) GPTD-PT or 
DTMR-PT.
Execute the 
test board PCSS long rep 3
 command where PCSS is the 
address (that is, port network number, carrier designation, and slot 
address) of the Tone Detector circuit pack or Call Classifier circuit pack 
containing the defective (alarmed) GPTD-PT or DTMR-PT.
If this does not clear the TTR Level alarm, proceed to Step 5.
5. At this point, the only way to clear the alarm is to replace the Tone Detector 
circuit pack or Call Classifier circuit pack containing the defective 
(alarmed) GPTD-PT, DTMR-PT or CLSFY-PT.
Hardware Error Log Entries and Test to Clear 
Valu es
Table 3-509. TTR Level Error Log Entries
Error 
Type
Aux 
Data Associated Test Alarm Level
On/Off 
Board Test to Clear Value
1 (a) 1 None
2 (b) 2 WARNING (See the 
WARNING message 
below)
OFF
3 (c) 3 None
4 (d) 4 WARNING OFF
5 (e) 5 None
6 (f) 6 WARNING OFF
7 (g) 7 MAJOR OFF
8 (h) 8 MINOR OFF
9 (i) 9 MINOR OFF