User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
 Maintenance Objects
3-1148TRANS-ID (Translation-ID) 
3
Processor circuit pack replacement
When replacing a processor circuit pack, follow the procedures in Table 3-505:
■ Standard Reliability:
— Begin the procedure with
 Step #3
.
■ High and Critical Reliability:
— Follow the procedure through once. Work on the standby side first, 
then on the active side.
NOTE:
Translations loaded from a duplicated system flash card into a simplex 
system, even where one of the translation IDs on the flash card 
corresponds to the ID on the processor, results in translation ID mismatch.
Table 3-505. Processor circuit pack replacement procedure
√ Step Description Command Procedure
1. Supress alarms change 
system-parameters 
maintenance
Change the Alarm 
Origination to OSS 
Numbers field to neither 
(Screen 3-5
).
Press Enter to effect the 
changes.
2. Busyout the standby 
PPN
busyout 
standby-spe
3. Remove the old 
processor circuit pack
Unlatch the old processor 
circuit pack and slide it out of 
its slot (no power-down 
required).
4. Replace the 
processor
Slide the replacement 
processor circuit pack in the 
slot and latch securely.
5. System detects ID 
mismatch
The system detects the 
translation ID mismatch, 
displays the warning message, 
and generates a MAJOR alarm 
(TRANS-ID).
6. Release standby PPN release standby-spe Releases the standby PPN.
Continued on next page