 Maintenance Objects
3-1120TIE-TRK (Tie Trunk) 
3
Table 3-494. Seizure Tests (#73, #747, #73) 
Error 
Code
Te st 
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The trunk may 
be busy with a valid call. Use the display trunk xx to determine the trunk 
group/member number of the port. Use the status trunk command to 
determine the service state of the port. If the service state indicates that 
the port is in use, then the port is unavailable for certain tests. You must 
wait until the port is idle before retesting. 
1. If the port status is active, but the port is not in use (no calls), then 
check the Error Log for Error Type 1025 (see Error Log table for 
description of this error and required actions). The port may be locked 
up. The far-end PBX may not be releasing.
2. If the port status is idle, then retry the command at 1-minute intervals a 
maximum of 5 times. 
1004 ABORT (Non-TN497 circuit packs only.) The port was seized by a valid call during 
the test. The test has been aborted. Use the display trunk xx to determine 
the trunk group/member number of the port. Use the status trunk 
command to determine the service state of the port. If the service state 
indicates that the port is in use, the port is unavailable for certain tests. You 
must wait until the port is idle before retesting.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1005 ABORT This test is not valid for this trunk translation. For this test to run, a delay 
dial trunk (or, for non-TN497 circuit packs, a wink-start trunk) must be in 
effect, and the trunk must be outgoing or two-way. Also, for the TN2140B, 
the trunk must be continuous-seize-ack or discontinuous-seize-ack.
1. Check trunk translation. If it is not a wink-start or delay dial trunk, this 
abort message should be ignored. (For the TN2140B, disregard this 
abort on a trunk that is not continuous-seize-ack or 
discontinuous-seize-ack.)
1018 ABORT Test disabled via administration.
1. Verify that the 
Maintenance Tests? field on the Trunk Group 
Form is set to n. To enable the test, issue the change trunk-group x 
command where "x" equals the number of the trunk group to be tested. 
Then change the entry in the 
Maintenance Tests? field on the 
form to y.
Continued on next page