DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
 Maintenance Objects
3-1104TIE-DS1 (DS1 Tie Trunk) 
3
FAIL The far-end trunk did not respond to the seizure of the near-end trunk 
within the allowable time period. This test could have associated in-line 
errors in the error log.
1.  1) Enter the list configuration board PCSS command. If the circuit 
pack is a TN767B vintage 8 or 9, a failure of test 136 causes a 
subsequent failure of test 7 due to a firmware bug. Eventually, the 
board and all of its ports will be taken out of service and extraneous 
on-board alarms will be generated. Replace the circuit pack with a 
TN767C V3 or later.
2. Verify that the ’Trunk Type’ field on the ’Trunk Administration’ screen 
matches the trunk type administered on far-end switch.
3. Look for DS1-BD or UDS1-BD errors in the hardware error log. If 
present, refer to the DS1-BD (DS1 trunk circuit pack) Maintenance 
documentation or to the UDS1-BD (UDS1 trunk circuit pack) 
Maintenance documentation.
4. Retry the test at 1-minute intervals for a maximum of 5 times.
2000 FAIL Response to the seizure message was not received within the allowable 
time period.
1. Enter the list configuration board PCSS command. If the circuit pack 
is a TN767B vintage 8 or 9, a failure of test 136 causes a subsequent 
failure of test 7 due to a firmware bug. Eventually, the board and all of 
its ports will be taken out of service and extraneous on-board alarms 
will be generated. Replace the circuit pack with a TN767C V3 or later.
2. Verify that the 
Trunk Type field on the Trunk Administration screen 
matches the trunk type administered on far-end switch.
3. Look for DS1-BD or UDS1-BD errors in the hardware error log. If 
present, refer to the DS1-BD (DS1 trunk circuit pack) Maintenance 
documentation or to the UDS1-BD (UDS1 trunk circuit pack) 
Maintenance documentation.
4. Retry the test at 1-minute intervals for a maximum of 5 times.
PASS The trunk can be seized for an outgoing call.
Table 3-489. TEST #136 DS1 Tie Trunk Seizure Test — Continued
Error 
Code
Te s t 
Result Description/ Recommendation
Continued on next page