 Maintenance Objects
3-1048TBRI-PT (TN2185 ISDN Trunk-Side BRI Port) 
3
Layer 3 Query Test (#1243)
This test is nondestructive. This test is used to check the application layer 
communications across the in-service ISDN D-Channel. The test passes if a 
status enquiry message was successfully sent, fails if the signaling link is down, 
and aborts if a query is already running or there is an internal error.
4 FAIL Received a status of Level 1 Pending Activation, the NT1 has a loss of 
power indicating a problem with the NT1.
1. Follow the manufacturer-recommended repair procedures for the NT1.
2. Execute the test port PCSSpp command and review the results of the 
Level 1 Status Inquiry test to verify the repair.
PASS This test indicates that Level 1 is activated or that software has taken the 
port out of service.
Table 3-465. TEST #1243 Layer 3 Query 
Error 
Code
Te s t 
Result Description/ Recommendation
1019 ABORT Test is already running.
1113 ABORT The signaling link is down.
1. Use the test port PCSSpp long command to clear any errors which 
prevent establishment of the signaling link.
2. Examine the results of Test #626, which is executed with the 
command. If this test aborts or fails, follow the repair procedure for the 
Signaling Link Status Test.
1141 ABORT The PKT-INT is out-of-service.
1. Consult the repair procedure for PKT-INT.
Continued on next page
Table 3-464. TEST #1242 Level 1 Status Inquiry — Continued
Error 
Code
Te s t 
Result Description/ Recommendation
Continued on next page