User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
 Maintenance Objects
3-1038TBRI-PT (TN2185 ISDN Trunk-Side BRI Port) 
3
System Technician-Demanded Tests: Descriptions 
and Error Codes
When inspecting errors in the system, always investigate tests in the order listed 
below. By clearing error codes associated with the 
Control Channel Loop Around 
Te s t ,
 for example, you may also clear errors generated from other tests in the 
testing sequence.
Clear Error Counters Test (#270)
This test is nondestructive. This test clears the various error counters associated 
with each TBRI-PT. This test passes if Maintenance is able to successfully send 
the downlink messages; otherwise, the test aborts.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence D/ND
1
1. D = Destructive; ND = Nondestructive
BRI Local LAN Port Loop Around Test (#618) X D
BRI TDM Port Loop Around Test (#619) X D
L1 State Query Test (#1242) X X D
CRC Error Counter Test (#623) X ND
Receive FIFO Overflow Test (#625) X ND
Layer 3 Query Test (#1243) X ND
Slip Query Test (#1244) X X ND
Clear Error Counters Test (#270) X X ND
NPE Crosstalk Test (#617) X D
Table 3-458. TEST #270 Clear Error Counters 
Error 
Code
Te st 
Result Description/ Recommendation
Any ABORT Maintenance could not send the downlink message.
PASS The message to clear the error counters of the TBRI-PT maintenance 
object has been sent.
Continued on next page