User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
 Maintenance Objects
3-1011SYS-LINK (System Links) 
3
Common procedure for repairing link problems
The state of a system link is dependent on the state of the various hardware 
components that it travels over. To resolve any problems associated with a 
system link, use the following procedure.
The switch maintains a list of hardware components over which the link travels 
called the hardware path. There are two hardware paths, the current hardware 
path and the faulted hardware path for each of the system links. The current 
hardware path is present only for those links that are currently up. When a link is 
down, the current hardware path is empty. The faulted hardware path, is always 
present once the link has gone down and is 
not cleared when the link 
subsequently recovers.
 The faulted path preserves the path that the link 
traversed when it last went down. The time at which the faulted path was last 
recorded is preserved and is accessible through the 
status sys-link
 location 
and 
list sys-link
 commands. Therefore, the focus of attention for problems which 
do not involve a link that is down, is the current hardware path. If the link is down, 
faulted hardware path is the focus of attention.
The command 
status sys-link
 location will present the state of both the 
hardware paths (current and faulted) along with the state of each of the 
components in the hardware path. When analyzing any system link problem, look 
for alarms on the components listed under desired hardware path. If any alarms 
are present, then follow the maintenance procedures for the alarmed 
components to clear those alarms first.
When all the components are alarm free, wait for 3 minutes to allow the links to 
recover. Test the system link through 
test sys-link PCSSpp long clear
 and 
notice any tests that fail. If any failures are found, fix the problems indicated by 
the tests and repeat the procedure.
Error Log Entries and Test to Clear Values
Table 3-448. SYS-LINK Error Log Entries 
Error 
Type
Aux 
Data Associated Test
Alarm 
Level
On/Off 
Board Test to Clear Value
13 (a) System Link Status 
(985)
WARNING OFF
257 (b) WARNING OFF test sys-link PCSSpp l cl
513 (c) WARNING OFF test sys-link PCSSpp l cl
772 (d) WARNING OFF test sys-link PCSSpp l cl
1025 (e) WARNING OFF test sys-link PCSSpp l cl
1281 (f) WARNING OFF test sys-link PCSSpp l cl
Continued on next page