DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
 Maintenance Objects
3-1005SYNC (Synchronization) 
3
Figure 3-41. Synchronization Timing Loop
A correctly designed network has no loops and each piece of equipment in the 
network is supplied by a clock of equal or lower stratum (that is, the inputs to a 
Stratum 3 clock should NEVER be from a Stratum 4 device). 
It is strongly 
recommended that the network administrator be consulted before 
administering any synchronization changes.
Error Log Entries and Test to Clear Values
Table 3-446. Synchronization Error Log Entries 
Error Type
Aux 
Data Associated Test
Alarm 
Level
On/Off 
Board Test to Clear Value
0
1
0 Any Any Any test synchronization
1 (a)
1
Any None WARNING/ 
MINOR(j)
2
OFF None
18 (b) 0 disable sync WARNING OFF enable sync
257 (c)
1
Any None WARNING/ 
MINOR(j)
2
OFF None
513 (d)
1
Any None WARNING/ 
MAJOR(j)
2
OFF None
Continued on next page
SYNCHRONIZATION REFERENCE
(PRIMARY OR SECONDARY)
CORRECT TIMING
DISTRIBUTION
"DEFINITY"
COMMUNICATONS
SYSTEM
GENERIC 2
"DEFINITY"
COMMUNICATONS
SYSTEM
"DEFINITY"
COMMUNICATONS
SYSTEM
"DEFINITY"
COMMUNICATONS
SYSTEM
GENERIC 1  GENERIC 1  GENERIC 1
TIMING LOOP
NOTE:
"DEFINITY"
COMMUNICATONS
SYSTEM
GENERIC 2
"DEFINITY"
COMMUNICATONS
SYSTEM
GENERIC 1