User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
 Maintenance Objects
3-951PR-MAINT (Maintenance Processor) 
3
MTP Sanity Handshake Test (#106)
This test is a nondestructive test. The MTP Sanity Handshake Test is simply a 
query from a maintenance process to the MTP. The MTP must reply for the test to 
pass.
MTP Manager I Loop Around Test (#228)
This test is a nondestructive test. The test places the Manager I channel of the 
MTP into a loop around mode, and it verifies the data integrity of the channel. 
Although the test is nondestructive, it causes loss of keyboard input from the PPN 
Manager I.
Table 3-411. TEST #106 MTP Sanity Handshake Test 
Error 
Code
Te s t 
Result Description/ Recommendation
1029 
2014 
2015 
2016 
2017 
2018 
2020 
2022 
2024 
2025 
2051
ABORT Refer to STBY-SPE Maintenance documentation for a description of these 
error codes.
1000 ABORT System software resources required to run this test are not available.
2033 ABORT  Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The MTP did not respond to the Sanity Handshake Query.
1. Re-enter command with the "long" option.
2. If the test continues to fail, replace the Processor circuit pack.
PASS The MTP responded to the Sanity Handshake Query.
Continued on next page