User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
 Maintenance Objects
3-916PMS-LINK (Property Management System Link) 
3
Hardware Error Log Entries and Test to Clear 
Valu es
Notes:
a. The PMS Link has been busied out for system technician-demanded 
maintenance via the 
busyout pms-link
 command. The link is torn down. 
Enter the 
release pms-link
 command to restore the link.
Table 3-393. PMS-LINK Error Log Entries 
Error 
Type
Aux 
Data Associated Test
Alarm 
Level
On/Off 
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate 
test description and follow the recommended procedures.
0 Any Any Any test pms sh r 1
18 (a) 0 busyout pms-link WARNING OFF release pms-link
257 (b) 0-6,
99,
255
Link Retry Test 
(#215)
MINOR/ 
WARNING
2
2. Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the set 
options command.
OFF test pms-link l
513 (c) 0-6,255 None test pms-link
769 (d) 0-6,255 None
1025 (e) 4x
3
3. Is any integer.
None
1281 (f) 1x
3
None
1537 (g) Nx
3
None
1793 (h) 0-6,255 None test pms-link
2049 (i) 0-6,255 None
2305 (j) 5x
3
None release pms-link or test 
pms-link
2561 (k) 0-6,255 None test pms-link
2817 (l) 10x
3
20x
3
30x
3
None
3073 (m) 7x
3
None
3841 (n) 2x
3
None
Continued on next page