User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
 Maintenance Objects
3-913PKT-INT (Packet Interface) 
3
Table 3-392. TEST #889 Reset Test 
Error 
Code
Test 
Result Description/ Recommendation
1334 ABORT The Packet Interface command queue is full. This should be a temporary 
condition caused by a high rate of commands being sent to a Packet 
Interface. Continued operation with a full command queue will cause a 
system WARM restart that may escalate to more severe restart levels.
1. Retry the command at 10 second intervals, a maximum of 5 times.
1362 ABORT The Reset test is not allowed to run because the Packet Interface is in 
service. Resetting a Packet Interface that is in-service is not allowed, since 
this is a destructive test.
1. Use the status packet-interface command to determine the service 
state of the Packet Interface. If the state is “out-of-service,” try the Reset 
command again.
2000 ABORT Response to the test request was not received within the allowable time 
period. 
1. Retry the command at 1-minute intervals, a maximum of 3 times.
2500 ABORT Internal system error
1. Retry the command.
NO 
BOARD
The Packet Interface circuit pack is not detected as being physically 
present.
1. Reboot the system, then retry the command. If the NO BOARD 
indication persists, replace the TN798 Processor circuit pack.
5001 FAIL The TDM clock has failed.
1. Refer to the TDM-CLK to clear this failure.
5002 FAIL The Packet Bus has failed.
1. Refer to PKT-BUS to clear this failure.
Any 
Other 
Than 
Those 
Listed 
Above
FAIL The Packet Interface diagnostic tests failed. The reset will run only on 
demand if the Packet Interface is in an out-of-service state. 
1. Retry the command 
reset packet-interface
2. If the reset fails, replace the TN798 Processor circuit pack.
PASS The Packet Interface diagnostic software passed. The Packet Interface is 
put back into service automatically.
Continued on next page