 Maintenance Objects
3-889PKT-BUS (Packet Bus) 
3
d. The Maintenance/Test Packet Bus port has detected open leads on the 
Packet Bus. The Aux Data value indicates the number of open leads.
e. Packet circuit pack, port, and endpoint maintenance has been disabled 
due to a Packet Bus failure. The Aux Data value indicates which sources 
have reported errors that have caused maintenance to be disabled. These 
sources include the following:
■ In-line errors from Packet circuit packs.
■ Packet Bus fault report from the Maintenance/Test Packet Bus port.
The Aux Data values that indicate these sources are identified in the 
following table:
NOTE:
It is important to remember that problems reported by Packet circuit 
packs may be caused by 
any
 circuit pack. However, only Packet 
circuit packs can detect such problems (inasmuch as TDM-only 
circuit packs are not affected by these problems).
f. Packet circuit pack, port, and endpoint maintenance has been disabled 
due to more than one circuit pack reporting in-line errors. If this occurs 
more than three times in 15 minutes (that is, if maintenance is disabled 
due to errors and then re-enabled because no more errors are reported), a 
Minor alarm is raised against the Packet Bus. Note that this error may still 
be present in the error log even if the "Circuit Pack Audit Test" reports that 
only one circuit pack has indicated a problem. This occurs if more than 
one circuit pack reported errors with in any one minute interval since the 
Packet Bus fault occurred.
Aux Data
Packet Circuit 
Pack
Maint/Test 
Circuit Pack
1X
2X
3XX
4
5X
6X
7XX