User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
 Maintenance Objects
3-859OPS-LINE (DS1 OPS Line) 
3
1020 ABORT The test did not run due to an already existing error on the specific port 
or due to a more general error on the circuit pack.
1. Examine the error log for existing errors against this port or the 
circuit pack and attempt to diagnose the already existing error. 
(Error code 1793 indicates a problem with the DS1 interface board, 
and any problems on the associated DS1-BD or UDS1-BD should 
be resolved first.)
2000 ABORT The test was aborted because response to the test was not received 
within the allowable time period.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2. If the test aborts with error code 2000 again, run short test 
sequence on the associated DS1-BD or UDS1-BD. If tests 138 
through 145 on the associated DS1-BD or UDS1-BD are also 
aborting with error code 2000, hyperactivity on the board or facility 
is indicated. In this case, the hyperactivity problem should be dealt 
with first.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Any FAIL The NPE of the tested port did not conference the tones correctly. This 
can cause noisy and unreliable connections.
1. Enter the list configuration board PCSS command. If the circuit 
pack is a TN767B vintage 8 or 9, replace the circuit pack with a 
TN767C V3 or later. The error log may have error type 1281 entries.
2. Test all administered trunks on the board. If one fails, this could be 
an off-board problem (such as an incoming seizure or an off-hook 
port seizure during the test). Retest the board.
3. If all of the ports fail, check the CARR-POW (see note below).
4. If several ports fail, check the error log for TONE-BD or TONE-PT 
errors. If there are such errors, take the appropriate action. When 
the TONE errors have cleared, rerun the test.
5. If the retry passes and troubles have been reported, coordinate 
isolation with the far-end PBX. Make sure that the near-end and 
far-end switches and any NTCE equipment (the CSUs) have the 
correct administration.
6. Replace the circuit pack.
NOTE:
If the conference circuit test fails for all ports on a circuit pack, a 
-5 volt power problem is indicated. 
Table 3-372. TEST #7 Conference Circuit Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page