User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
 Maintenance Objects
3-837MMI-BD 
3
TSI Crosstalk Test (#6)
This test is non-destructive. The Time Slot Interchanger (TSI) chip controls 
connectivity to the TDM bus. The TSI Cross Talk Test verifies that this TSI talks on 
the selected TDM bus time slot and never crosses over to time slots reserved for 
other connections. If the TSI is not working correctly, one-way and noisy 
connections may occur. If the test passes, then the TSI is able to communicate 
over the TDM bus. This test is part of the circuit pack’s demand and scheduled 
long test sequence, and takes approximately 20 to 30 seconds to complete.
Table 3-362. System Technician-Demanded Tests: MMI-BD
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
Reset Board 
Sequence D/ND
1
1. D = Destructive, ND = Non-destructive
TSI Crosstalk (#6) X ND
TSI Looparound Test (#1108) X ND
MMI SYNC Status Test (#1123) X ND
MMI SYNC Status Test (#1122) X ND
Control Channel Looparound Test (#52)
2
2. Refer to the repair procedure described in XXX-BD (Common Port Circuit Pack) for a description 
of this test.
XX ND
SAKI Sanity Test (#53)
2
XD
Continued on next page
Table 3-363. TEST #6 TSI Crosstalk Test
Error 
Code
Test 
Result Description/Recommendation
ABORT Internal system error. This is an abnormal abort.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test, the traffic load on the 
system is very high, or the time slots are out-of-service due to TDM-BUS 
errors. Refer to ‘‘TDM-BUS (TDM Bus)’’
 to diagnose any active TDM Bus 
errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic, 
repeat the test at 1-minute intervals a maximum of 5 times.