3-809MEDPROPT (TN802 MED PRO DSP PORT) 
3
TDM NIC Looparound Test (#1380)
This test is non-destructive
This test sets up a loopback path from the TDM bus out to the NIC edge of the 
Media processor and back to the TDM bus. The loopback is established by 
setting up the outbound IP connection to send IP packets to the MedPro’s own IP 
address. The tone generator places a test tone (440Hz) onto a timeslot. The 
timeslot is listened to by the Media processor board. The tone is routed through 
the TAP802 DSP farm, where it may undergo transcoding to G.723, etc. The tone 
is looped back at the Network interface and back through the TAP802 where it is 
converted back into standard PCM. The tone is placed onto a TDM timeslot and 
detected by a tone detector port. The test passes if 440Hz is reported by the 
tone detector
1-11 FAIL Some DSPs on the circuit pack have failed. The FAIL code is the number of 
bad DSPs reported.
PASS All 11 DSPs are functioning and in-service. 
0NO 
BOARD
No board was detected by the test.
1. Check the Error Log for wrong board (Error Type 125) or no board (Error 
Type 131). Resolve either of these issues, if applicable.
2. Check that the board is properly translated and inserted. If so, check for 
hyperactivity. If hyperactive, use the reset board UUCSS command.
3. Run the test again. If it fails, the circuit pack may be bad. Replace the 
circuit pack and retest.
Table 3-351. DSP Capacity Query Test (#1382) — Continued
Error 
Code
Te s t 
Result Description/ Recommendation
Continued on next page