User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
 Maintenance Objects
3-807MEDPROPT (TN802 MED PRO DSP PORT) 
3
Notes:
a.
Error Type 1
 - this error type indicates that less than three DSPs are out of 
service (OOS), and no alarm is raised. The Aux Data field contains the 
number of DSPs that are Out of Service (OOS).
b.
Error Type 258
 - this error type indicates that more than three, but less 
than 9 DSPs are out of service (OOS), and a WARNING alarm is raised. 
The Aux Data field contains the number of DSPs that are Out Of Service 
(OOS).
c.
Error Type 515
 - this error type indicates that all DSPs are out of service 
(OOS), and a MINOR alarm is raised. The Aux Data field contains the 
number of DSPs that are Out Of Service (OOS).
d.
Error Type 18
 - the MEDPRO has been busied out by a 
busyout port 
UUCSS
 command.
1. Release the port (
release port UUCSS
).
515(c) DSP Capacity 
Query Test 
(##1382)
MINOR ON test board UUCCSS l r5
18(d) 0 busyout port 
UUCSS
WARNING OFF release port UUCCSS
769 Any TDM NIC 
Looparound Test 
(#1380)
MIN ON test port UUCCSS l r10
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Table 3-349. MEDPROPT Error Log Entries — Continued
Error 
Type
Aux 
Data Associated Test
Alarm 
Level
On/Off 
Board Test to Clear Value
Continued on next page