User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
 Maintenance Objects
3-795MEDPRO (Media Processor MAPD Circuit Pack) 
3
Error Log Entries and Test to Clear Values
Notes:
a.
Error Type 1
 -This error indicates that the circuit pack has totally stopped 
functioning or is not fully administered. The alarm is logged about 15 
minutes after the circuit pack has been removed or 11-minutes after the 
SAKI Test (#53) fails.
Table 3-341. DS1 Interface Circuit Pack Maintenance Error Log Entries
Error 
Type
Aux 
Data Associated Test
Alarm 
Level
On/Off 
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test board UUCSS
1(a) 0 Circuit pack removed or 
SAKI Test (#53)
MIN/WRN
2
2. If ports are assigned to the circuit pack, then a minor alarm is raised. If no ports are assigned to
the circuit pack, then a warning alarm is raised. The alarm is raised after the circuit pack has been
missing for a period of 15 minutes. Warning alarms are also raised against any ports administered
on the circuit pack.
ON
18(b) 0 busyout board UUCSS WARNING OFF release board UUCSS
23(c) 0 WARNING OFF add ds1 UUCSS
125(d) None None MIN/WRN
3
3. Minor alarms on this MO may be downgraded to warning alarms based on values set in the set
options command.
ON
257(e) 65535 Control Channel Loop Test 
(#52)
MINOR ON test board UUCSS l r 2
257(e) Any None
1538 Any Hyper activity MIN/WRN
3
ON
1793 Any NIC Los Of Signal MIN/WRN
3
test board UUCSS l r 2
2049(f) Any NT PC Failure MIN/WRN
3
reset board UUCSS
2305 Any IP Address Inconsistency test board UUCSS l r 2
2561 Any Ping Error MIN/WRN
3
test board UUCSS l r 5
3841(g) 4358 Log Only
3999(h) Any None
Continued on next page