User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
 Maintenance Objects
3-789MAPD-BD (MAPD Interface Circuit Pack TN802) 
3
2100 ABORT System resources required for this test are not available.
1. Retry the reset board command at 1-minute intervals a maximum of 5 
times.
1 FAIL The circuit pack failed to reset.
2 FAIL The circuit pack failed to restart.
1. Execute the reset board command again.
2. If the problem persists, replace the circuit pack.
PASS The circuit pack initializes correctly.
1. Run the Short Test Sequence.
0NO 
BOARD
The test could not relate the internal ID to the port (no board). This could be 
due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute the add ds1 
UUCSS command to administer the MAPD interface if it is not already 
administered.
2. If the board was already administered correctly, check the error log to 
determine whether the board is hyperactive. If this is the case, the board 
is shut down. Reseating the board re-initializes the board.
3. If the board was found to be correctly inserted in step 1, then issue the 
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
Table 3-331. TEST #53 SAKI Sanity Test — Continued
Error 
Code
Te s t 
Result Description/ Recommendation
Continued on next page