 Maintenance Objects
3-788MAPD-BD (MAPD Interface Circuit Pack TN802) 
3
SAKI Sanity Test (#53)
This test is destructive.
This test resets the circuit pack. The test is highly destructive and can only be 
initiated by a system technician-demanded 
reset board UUCSS
 command.
PASS Communication with this circuit pack is successful.
0NO 
BOARD
The test could not relate the internal ID to the port (no board). This could be 
due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute the add ds1 
UUCSS command to administer the MAPD interface if it is not already 
administered.
2. If the board was already administered correctly, check the error log to 
determine whether the board is hyperactive. If this is the case, the 
board is shut down. Reseating the board re-initializes the board.
3. If the board was found to be correctly inserted in step 1, then issue the 
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
Table 3-331. TEST #53 SAKI Sanity Test 
Error 
Code
Te s t 
Result Description/ Recommendation
None ABORT System resources required for this test are not available.
1. Retry the reset board command at 1-minute intervals a maximum of 5 
times.
1015 ABORT Port is not out-of-service.
1. Busyout the circuit pack (busyout board UUCSS).
2. Execute the reset board command again.
Continued on next page
Table 3-330. TEST #52 Control Channel Looparound Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page