User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
 Maintenance Objects
3-780MAPD-BD (MAPD Interface Circuit Pack TN802) 
3
Notes:
a. Error Type 1: indicates that the circuit pack has totally stopped functioning 
or is not fully administered. The alarm is logged about 15 minutes after the 
circuit pack has been removed or 11 minutes after the SAKI Test (#53) 
fails.
To be fully administered, a MAPD circuit pack must meet all of these 
conditions:
■ Have an entry in the circuit plan (
change circuit pack
)
■ Be administered (
add ds1 UUCSS
)
■ Be physically inserted into the correct slot
If the circuit pack has an entry in the circuit plan and either of the other two 
conditions are 
not
 met, a MINOR alarm is logged. To resolve the error, 
either:
1. Make sure the circuit pack is properly administered and that a 
functioning MAPD circuit pack is inserted in the correct slot, OR
3585 to 
3601 (o)
Any Misframe Alarm Inquiry 
Test (#145)
MIN/ 
WRN
3
OFF test board UUCSS r 6
3840 (p) Any None
3841 (q) 4358
3842 (r) 46097
3843 (s) 46081
3999 (t) Any None
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
2. If ports are assigned to the circuit pack, then a minor alarm is raised. If no ports are assigned to 
the circuit pack, then a warning alarm is raised. The alarm is raised after the circuit pack has been 
missing for a period of 15 minutes. Warning alarms are also raised against any ports administered 
on the circuit pack.
3. Minor alarms on this MO may be downgraded to warning alarms based on values set in the set 
options command.
4. Major alarms on this MO may be downgraded to minor or warning alarms based on values set in 
the set options command.
Table 3-326. MAPD (TN802) Error Log entries — Continued
Error 
Type
Aux
Data Associated Test
Alarm
Level
On/Off 
Board Test to Clear Value
Continued on next page