DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
 Maintenance Objects
3-768MAPD-BD (MAPD Interface Circuit Pack TN802) 
3
PSTN fallback feature
The Public Switched Telephone Network (PSTN) fallback feature is available on 
the Internet trunk application software, which periodically pings the remote 
destinations that the software calls. When the far end returns a poor response 
time to the ping, DEFINITY’s ARS or AAR network routing patterns bypass those 
ports and direct the call to another port, typically on a PSTN trunk.
When the remote destinations show acceptable response times to subsequent 
pings, the corresponding ports are returned to “idle,” where they are available for 
service.
Cabinet configuration
Because of overheating, the TN802 circuit pack should not be placed directly 
above or below another MAPD circuit pack.
UPS protection
Because Windows NT is more vulnerable to damage from a power interruption 
than the DEFINITY ECS, uninterrupted power supply (UPS) protection is strongly 
recommended for systems using the TN802 circuit pack. 
Table 3-322. Restore TN802 administration data
Step Description Comments
1. Restore IP Trunk 
administration
At the Windows NT desktop, double-click on the 
IP Trunk Back UP Restore icon.
The IP Trunk Backup/Restore Utility screen 
appears.
2. Select utility In the IP Trunk Backup/Restore Utility dialog 
screen, click Files, Restore.
The IP Trunk Backup screen appears
3. Select restore In the IP Trunk Backup screen, click on the 
Restore button.
4. Wait Wait until the yellow Disk-In-Use LED (Note 5 in 
Figure 3-29
) light is out.
Continued on next page