User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Objects 
3-673H323-SGRP (H.323 Signaling Group) 
3
System Technician-Demanded Tests: Descriptions 
and Error Codes
Always investigate tests in the order presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the 
CLAN Ethernet Status Test (#1386)
, for example, you may also clear errors 
generated from other tests in the testing sequence.
CLAN Ethernet Status Test (#1386)
This test is non-destructive.
This test checks the status of the C-LAN ethernet port that originated this 
signaling group. If the C-LAN ethernet port is in-service, the test passes, if it is 
out of service the test fails.
NOTE:
Failure of this test puts the SIG-GRP in the OOS state.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence D/ND
1
1. D = Destructive; ND = Nondestructive
CLAN Ethernet Status Test (#1386) X X ND
MedPro Status Test (#1392) X X ND
H.323 Signaling Group Ping Test (#1387) X X ND
Table 3-281. TEST #1386 CLAN Ethernet Status Test
Error 
Code
Tes t 
Result Description/ Recommendation
2500 ABORT Internal system Error.
1. Retry the command at 1-minute intervals a maximum of 3 times
2800 ABORT A C-LAN ethernet port that corresponds to the near-end address of the 
signaling group has not been administered.
FAIL The C-LAN ethernet port that corresponds to the near-end address of this 
signaling group and all trunk members controlled by this signaling group 
are out of service.
1. Check the system for errors against the out of service C-LAN board.
Continued on next page