User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Objects 
3-647ETH-PT (Control LAN Ethernet) 
3
Aux Data indicates the internal application number.
g.
Error Type 2305-2816
: System software detected a session is down. Aux 
Data indicates the session number. These are log only errors. Error types 
2305-2560 are for session numbers 1-256. Error types 2561-2816 are for 
session numbers 257-512.
h.
Error Type 3329
: TCP/IP Ping Test failed. 
1. Test port (
test port UUCSSpp short
).
2. Refer to TCP/IP Ping Test (#1281) repair procedures.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Investigate errors in the order they appear in the table below.
Error Type Application
1793 Unused
1794 DCS
1795 AUDIX
1796 CMS
1797 ISDN Gateway
1798-1920 Reserved for 
future
Table 3-267. System Technician-Demanded Tests: ETH-PT
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence D/ND
1
1. D = Destructive, ND = Non-destructive
Ethernet Local Loop-Around Test (#1278) X D
TCP/IP Ping Test (#1281) X X ND
Session Status Test (#1286) X X ND
Link Integrity Inquiry Test (#1282) X X ND