This test cannot be run on a trunk in any of the following conditions:
■ The trunk direction is administered as an incoming only trunk.
■ The trunk has been seized by a normal trunk call.
■ The trunk is administered with maintenance test disabled.
Table 3-225. TEST #314 DS1 CO Dial Tone Seizure Test 
Error 
Code
Te st 
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may 
be in use on a valid call. Use the status trunk command to determine 
when the port is available for testing.
1004 ABORT The port has been seized by a user for a valid call. Use the status trunk 
command to determine when the port is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1005 ABORT Test failed due to incompatible configuration administered in trunk group 
form.
1. Look at the trunk group administration form and see whether the trunk 
is incoming only, port 24 on a DS1 Interface with common control 
channel signaling, or an automatic CO type such as FX. Under any of 
these conditions this is a normal abort.
1018 ABORT Test has been disabled via administration.
1. Verify that the 
Maintenance Tests field on the Trunk Group Form 
is set to n. To enable the test, issue the change trunk-group x 
command where ‘‘x’’ equals the number of the trunk group to be 
tested. Then change the entry in the 
Maintenance Tests field on 
the form to y.
2. Repeat the test.
1020 ABORT The DS1 Interface circuit pack is out-of-service.
1. Look for UDS1-BD errors in the Hardware Error Log. If present, refer to 
the UDS1-BD (DS1/UDS1 Trunk Circuit Pack) Maintenance 
documentation.
2. Retry the command.
2000 ABORT Response to the test request was not received within the allowable time 
period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
Continued on next page