User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Objects 
3-525DIOD-DS1 (DS1 DIOD Trunk) 
3
Notes:
a. Error Type 1
—
Aux Data 57408
—No tip ground is detected on an outgoing 
call.
Aux Data 57476—Rotary Dial before Wink.
Aux Data 57477—Rotary Dial pulse too early.
Aux Data 57485—Wink too short for a valid signal.
Aux Data 57487—PBX could not get ‘‘loop close’’ signal
The DS1 Interface circuit pack detected a hardware fault. These errors will 
cause the Dial Tone Test (#314) to run and are only considered a problem 
if the Dial Tone Test fails (in which case Error Type 1025 will also show up). 
In this case, the trunk may be put in the ready-for-service state (shown as 
‘‘disconnected’’ by the status command), which allows only incoming 
calls. Run the Dial Tone Test (#314) and follow the procedures.
b. Error Type 15—This is a software audit error that does not indicate any 
hardware malfunction. Run Short Test Sequence and investigate 
associated errors (if any).
2049(j) 57473 
57474 
57475
2305(k) 50944
2562(l) 16665
2817(m) 52992
3840(n) Port Audit and 
Update Test (#36)
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
2. This alarm will only be raised when the System-Parameter Country form has the Base Tone 
Generator field set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this 
trunk group are out of service, then the alarm will be upgraded to a MAJOR alarm.
3. Major alarms on this MO may be downgraded to Warning alarms based on the value used in the 
set options command.
Table 3-221. DS1 DIOD Error Log Entries — Continued
Error 
Type
Aux 
Data Associated Test
Alarm 
Level
On/Off 
Board Test to Clear Value
Continued on next page