User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Objects 
3-510DIG-LINE (Digital Line) 
3
Only one value (Pass. Fail, or Abort) is generated as a result of the two tests run. 
If any test fails aborts, the sequence is stopped. Upon completion of this test the 
associated endpoint and port are moved back into the previous service state.
Table 3-215. TEST #1201 Digital Terminal Remote Loop Around Test 
Error 
Code
Te s t 
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may 
be busy with a valid call. Use the display port PCSSpp command to 
determine the station extension or attendant number of the port. Use 
status station or status attendant to determine the service state of the 
port. If the service state indicates that the port is in use, then the port is 
unavailable for certain test. You must wait until the port is idle before 
re-testing. Attendants are always in use (off-hook) if the handset is 
plugged in and the port is not busied out.
1. If the port status is idle, then retry the command at 1-minute intervals a 
maximum of 5 times.
1001 ABORT System resources required to run this test are not available.
1. If the port status is idle, then retry the command at 1-minute intervals a 
maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions or it may have time slots out-of-service due 
to TDM-BUS errors. Refer to TDM-BUS (TDM-Bus) Maintenance to 
diagnose any active TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic, 
repeat test at 1-minute intervals a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may 
be oversized for the number of Tone Detectors present or some Tone 
Detectors may be out of service.
1. Look for TTR-LEV errors in the Error Log. If present refer to TTR-LEV 
(TTR-Level) Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to TONE-PT 
(Tone Generator) Maintenance documentation.
3. If neither condition exist, retry the command at 1-minute intervals a 
maximum of 5 times.
Continued on next page